Full Guide
Turn on captions Open panels
 (0:04) -Locate the ID tag under one of the sinks: this identifies the side of the station you must open to access plumbing 
-Using a H4 allen key, remove bolts from top and bottom panel on that side. 
-Also remove bottom panel on opposite side (this will help with leveling) 
Level the station (0:29)
 -Using a level, make sure all sides of the station are leveled. This is essential for stability of the station and for all sinks to drain properly. 
-Loosen the nut on the inside of station for each of the 4 legs
-Using an adjustable wrench, loosen & tighten the nut under the station for each of the 4 legs to adjust its height 
-Make sure the station is leveled and stable 
Add new filter (0:41) 
-Using the filter key, loosen the filter housing 
-Take out the old filter and empty water from housing (if applicable) -Unpack the new filter 
-Ensure the two rubber O-rings are in place 
-Place the new filter in the housing, centered on the cylinder 
-Align the filter housing O-ring and secure the housing with the key. 
Fill up, plug & turn on chillers (1:50) 
-Take off the round black caps off each chiller -Fill up the chillers to the fill line 
-Use water with total mineral concentration between 150-350 ppm Do not use hard water. 
Do not use distilled water. 
-If you are unsure, test your water, or use natural spring bottled water (you can look up the mineral concentration online to be sure) 
-Replace the round black caps 
-Plug in the chillers using a 3-prong 120V extension cord or outlet. 
-Put the 3 chillers in “ON” position 
-Wait a few seconds for the chillers to turn on. You can verify by listening or placing your hand on the chillers to make sure they are working. This can take a few seconds before they turn on. 
Incoming water (3:15) 
-Plug the food
- Grade (NSF) hose into the station, and into the water source 
-Place the main valve on the station to “OFF” 
Position Grey water drain (3:20) 
-Connect your grey water drain (heavy duty 2” backwash hose, 2” pvc pipe, or other 2” ID hose) to the flexible elbow 
-Connect the elbow to the main drain underneath the station
 -Tighten the clamp 
-Direct your grey water drain towards a nearby drain, ditch, or any area ready to receive drain water. connection overview* 
Turn on the water source (4:16) 
-Turn on the water at the main source 
-Turn on the main valve on the station 
-Flush the water 
-Flush the system by running water through the faucets 
-It is normal to have air bubbles at the start, once the air is out, the flow will be constant 
-Flush the system for 1-2 minutes (approximately 3 gallons) -Make sure to test all faucets 
Check for leaks (4:34) 
-Check inside the station for leaks 
-Verify all along the incoming water line : main valve, filter housing, manifold, chiller connections, faucets, etc 
-Verify the drains for leaks: near the sinks, grey water manifold (black, under chillers) and main drain connection Close the station 
(4:43) -Place the panels back on the station 
-Replace the bolts, and tighten them in place Install Umbrellas (5:01) 
-Install the umbrellas using 2 bolts per side 
-Push the umbrella upwards before tightening the bolts 
Admire your newly installed O’land water station (5:11)
Enjoy cooled & filtered water! Have a great season!